Re: Alt Field Circuit Breaker Popping


Mike Dwyer
 

Ok, great news.

Now disconnect the Field wire from the back of the alternator and leave hanging.
Does the 5A break still blow?  If it does it's a bad regulator.  If it doesn't blow now, then we may have a shorted field in the alternator.
 
: )
Mike