Re: Firewall electric thru connections
I think that is what Corbin showed a picture of and the MIL spec part number for. Am I wrong?
Jay
Sent from my Verizon Wireless 4G LTE DROID
Rik <Info@...> wrote:
Doesn’t everyone know what a canon
I think that is what Corbin showed a picture of and the MIL spec part number for. Am I wrong?
Jay
Sent from my Verizon Wireless 4G LTE DROID
Rik <Info@...> wrote:
Doesn’t everyone know what a canon
|
By
Jay Scheevel
·
#49258
·
|
|
Re: Firewall electric thru connections
Doesn’t everyone know what a canon plug connector is? The thermocouple wires are connected via a cannon plug on every turbine I’ve had along with the tach generator, temp sensor, frag’s etc..
Doesn’t everyone know what a canon plug connector is? The thermocouple wires are connected via a cannon plug on every turbine I’ve had along with the tach generator, temp sensor, frag’s etc..
|
By
Rik
·
#49257
·
|
|
Re: Firewall electric thru connections
Ha! Nope! All of this came about because Imraan and I were discussing this topic. Now you know that I was asking for Imraan (although he wasn't really interested) because he didn't want to have all
Ha! Nope! All of this came about because Imraan and I were discussing this topic. Now you know that I was asking for Imraan (although he wasn't really interested) because he didn't want to have all
|
By
Bruce Crain
·
#49256
·
|
|
Re: Firewall electric thru connections
Then that instrument is essentially a voltage meter (with a selector switch), that is calibrated to directly read in Degrees/Temperature, the voltage output of the EGT or CHT probe metals’ hot
Then that instrument is essentially a voltage meter (with a selector switch), that is calibrated to directly read in Degrees/Temperature, the voltage output of the EGT or CHT probe metals’ hot
|
By
Jay Scheevel
·
#49255
·
|
|
Re: Firewall electric thru connections
I suppose it is free standing? It is fairly old but has a toggle switching between egt/cht and each probe has two designated wires going all the way from the head to the probe.
Bruce
I suppose it is free standing? It is fairly old but has a toggle switching between egt/cht and each probe has two designated wires going all the way from the head to the probe.
Bruce
|
By
Bruce Crain
·
#49254
·
|
|
Re: Firewall electric thru connections
Can you send a picture of your gauge? Is it free standing with only inputs being the two thermocouple wires?
Sent from my Verizon Wireless 4G LTE DROID
Bruce Crain <jcrain2@...> wrote:
If the
Can you send a picture of your gauge? Is it free standing with only inputs being the two thermocouple wires?
Sent from my Verizon Wireless 4G LTE DROID
Bruce Crain <jcrain2@...> wrote:
If the
|
By
Jay Scheevel
·
#49253
·
|
|
Re: Firewall electric thru connections
If the instrument is “amplified signal” such as KN egt/cht gauge will it make a difference? The material coming out of the KN instrument is the same wire as the probe wires.
Bruce
If the instrument is “amplified signal” such as KN egt/cht gauge will it make a difference? The material coming out of the KN instrument is the same wire as the probe wires.
Bruce
|
By
Bruce Crain
·
#49252
·
|
|
Re: Firewall electric thru connections
Corrections for connectors of differing metals are difficult to do unless you know the temperatures on both sides of the junction in real time. This is practically impossible, since you would have
Corrections for connectors of differing metals are difficult to do unless you know the temperatures on both sides of the junction in real time. This is practically impossible, since you would have
|
By
Jay Scheevel
·
#49251
·
|
|
Re: Firewall electric thru connections
For those who are using connectors not if thermocouple material: a difference in temperature on the two sides of the connection will induce an error. It will be equal on each sensor so for EGT the
For those who are using connectors not if thermocouple material: a difference in temperature on the two sides of the connection will induce an error. It will be equal on each sensor so for EGT the
|
By
Rick Hole
·
#49250
·
|
|
Re: Firewall electric thru connections
I used to enjoy wiring up Canon plugs on A-4s. Had no idea on the dissimilar metals and "cold junctions." Can't the instrument be re-calibrated?
Found a pretty good primer on thermocouple
I used to enjoy wiring up Canon plugs on A-4s. Had no idea on the dissimilar metals and "cold junctions." Can't the instrument be re-calibrated?
Found a pretty good primer on thermocouple
|
By
Joe Hood <joe.hood@...>
·
#49249
·
|
|
Re: Firewall electric thru connections
Jay, that was just the point I was going to make. Any connections between thermocouple and instrument need to be same material or you will get a "Cold Junction". That can change the actual
Jay, that was just the point I was going to make. Any connections between thermocouple and instrument need to be same material or you will get a "Cold Junction". That can change the actual
|
By
Richard Thomson
·
#49248
·
|
|
Re: Firewall electric thru connections
Bruce do a search for bulkhead connector sub-d
That will get you multiple sources. The soldered ends aren't as common in aerospace use as soldering is seen as less reliable but can still be found as
Bruce do a search for bulkhead connector sub-d
That will get you multiple sources. The soldered ends aren't as common in aerospace use as soldering is seen as less reliable but can still be found as
|
By
kingdws@...
·
#49247
·
|
|
Re: Quickie Q1 / Q2 Material
There is a link at the bottom of the page that says Unsubscribe. Try that.
There is a link at the bottom of the page that says Unsubscribe. Try that.
|
By
Jay Scheevel
·
#49246
·
|
|
Re: Quickie Q1 / Q2 Material
Thank you.
By
overlormustafa <overlordmustafa@...>
·
#49245
·
|
|
Re: Quickie Q1 / Q2 Material
Totally understand. Then best option is to use the link below to unsubscribe. No password needed as it works as any other site. Or you could use the "forgot password" option and manage
Totally understand. Then best option is to use the link below to unsubscribe. No password needed as it works as any other site. Or you could use the "forgot password" option and manage
|
By
Corbin <c_geiser@...>
·
#49244
·
|
|
Re: Quickie Q1 / Q2 Material
I don't have a password as I did not sign up for the new group/forum...
I don't have a password as I did not sign up for the new group/forum...
|
By
overlormustafa <overlordmustafa@...>
·
#49243
·
|
|
Re: Quickie Q1 / Q2 Material
Easiest way is to do it yourself using the links available. You can unsubscribe or manage your subcription with the links.
Corbin Ge!ser
--
Corbin
N33QR
Easiest way is to do it yourself using the links available. You can unsubscribe or manage your subcription with the links.
Corbin Ge!ser
--
Corbin
N33QR
|
By
Corbin <c_geiser@...>
·
#49242
·
|
|
Re: Q-List Zoom meeting now uploaded to YouTube
Hey Kevin and Sam,
Unfortunately I was unable to participate Saturday. Kev I still love your MidWest humor. Great job guys. Be safe!
Jim
N46JP - Q200
Sent from Outer Space
From: main@Q-List.groups.io
Hey Kevin and Sam,
Unfortunately I was unable to participate Saturday. Kev I still love your MidWest humor. Great job guys. Be safe!
Jim
N46JP - Q200
Sent from Outer Space
From: main@Q-List.groups.io
|
By
Jim Patillo
·
#49241
·
|
|
Re: Quickie Q1 / Q2 Material
Can someone, pretty please, remove me from this list?
Can someone, pretty please, remove me from this list?
|
By
overlormustafa <overlordmustafa@...>
·
#49240
·
|
|
Re: Firewall electric thru connections
Bruce, I use one 24 pin Molex twist connector for everything including CHT/EGT.
Connector is bulkhead mounted on firewall in front of pax rudder pedals.
Jim
N46JP Q200
Sent from Outer Space
From:
Bruce, I use one 24 pin Molex twist connector for everything including CHT/EGT.
Connector is bulkhead mounted on firewall in front of pax rudder pedals.
Jim
N46JP Q200
Sent from Outer Space
From:
|
By
Jim Patillo
·
#49239
·
|